English-26
DISPLAY PROTECTION
POWER SAVE Sets how long the monitor waits to go into power save mode after the signal is lost.
NOTE: When connecting DVI, the display card might not stop sending the digital data even
though the image might have disappeared. If this occurs the monitor will not switch into power
management mode. POWER SAVE is disabled when AUTO OFF or CUSTOM is selected in
HUMAN SENSING.
AUTO
STANDBY
AUTO POWER SAVE The monitor automatically goes into OFF at the preset time period after signal is lost.
The monitor will return to normal mode when signal is restarted.
-
AUTO STANDBY The monitor automatically goes into OFF at the preset time period after signal is lost.
Press the power button to return to normal mode.
-
DISABLE The monitor will not goes into OFF after signal is lost. -
HEAT STATUS Displays status of the FAN, BACKLIGHT and TEMPERATURE. -
FAN CONTROL Cooling fan reduces the temperature of the display to protect from overheating.
If “AUTO” is selected, you can adjust the start temperature of the cooling fan and fan speed.
AUTO, HIGH
SCREEN SAVER Use the SCREEN SAVER function to reduce the risk of Image Persistence.
GAMMA
The display gamma is changed and fi xed when “ON” is selected. OFF
BACKLIGHT The brightness of backlight is decreased when “ON” is selected.
NOTE: Do not select this function when ROOM LIGHT SENSING is MODE1 or MODE2.
OFF
MOTION The screen image is slightly expanded and moves in 4 directions (UP, DOWN, RIGHT, LEFT) at
user determined intervals. You can set interval time and zooming ratio.
This function is disabled when PIP, STILL, TEXT TICKER or TILE MATRIX are enabled.
OFF
SIDE BORDER COLOR Adjusts the color of the side borders when a 4:3 image is displayed.
Press + button, the bar will become lighter.
Press - button, the bar will become darker.
15
CHANGE PASSWORD Allows the security password to be changed.
The factory preset password is 0000.
-
SECURITY Locks the security password.
START-UP LOCK: Security password is required when the monitor power is on.
CONTROL LOCK: Security password is required when the remote control button or control button
on the monitor is pressed.
BOTH LOCK: Security password is required when the monitor power is on, or the remote control
button or control button on the monitor is pressed.
OFF
RESET Resets the following settings within the DISPLAY PROTECTION menu back to factory setting:
POWER SAVE, FAN CONTROL, SCREEN SAVER, SIDE BORDER COLOR.
-
EXTERNAL CONTROL
IP ADDRESS SETTING NOTE: When changing the LAN SETTING, you need to wait several seconds until the LAN
SETTING is applied.
IP SETTING Enabling this option automatically assigns an IP address to the monitor from your DHCP server.
Disabling this option allows you to register the IP address or subnet mask number obtained from
your network administrator.
NOTE: Consult your network administrator for the IP address when “AUTO” is selected for
[IP SETTING].
AUTO
IP ADDRESS Set your IP address of the network connected to the monitor when “MANUAL” is selected for
[IP SETTING].
192.168.0.10
SUBNET MASK Set your subnet mask number of the network connected to the monitor when “MANUAL” is
selected for [IP SETTING].
255.255.255.0
DEFAULT GATEWAY
Set your default gateway of the network connected to the monitor when “MANUAL” is selected
for [IP SETTING].
NOTE: Set as [0.0.0.0] to delete the setting.
0.0.0.0
DNS Set for IP ADDRESS SETTING of DNS server.
AUTO: Automatically assign an IP address of DNS server connected to the monitor.
MANUAL: Set your IP address of DNS server connected to the monitor.
AUTO
DNS PRIMARY
Set your primary DNS settings of the network connected to the monitor.
NOTE: Set as [0.0.0.0] to delete the setting.
0.0.0.0
DNS SECONDARY Set your secondary DNS settings of the network connected to the monitor.
NOTE: Set as [0.0.0.0] to delete the setting.
0.0.0.0
MAC ADDRESS Displays the MAC ADDRESS. -
LAN POWER Selects LAN operation mode. When “ON” selected, allows to supply power to LAN during power
save mode or standby mode.
NOTE: For enabling “AUTO ID” or “AUTO TILE MATRIX SETUP”, this function should be ON.
OFF

Other manuals for NEC MultiSync P403

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NEC MultiSync P403 and is the answer not in the manual?

NEC MultiSync P403 Specifications

General IconGeneral
Panel life- h
Panel typeSPVA
Pixel pitch- mm
Response time8 ms
Display diagonal40 \
Display brightness700 cd/m²
Display technologyLED
Native aspect ratio16:9
Vertical scan range50 - 85 Hz
Horizontal scan range31.5 - 91.1 kHz
LED backlighting typeEdge-LED
Contrast ratio (typical)4000:1
Display number of colors-
Display diagonal (metric)101.6 cm
Active display area (W x H)885.6 x 498.15 mm
Supported graphics resolutions640 x 480 (VGA), 800 x 600 (SVGA), 1024 x 768 (XGA), 1280 x 1024 (SXGA), 1280 x 768 (WXGA), 1360 x 768 (WXGA), 1600 x 1200 (UXGA), 1920 x 1080 (HD 1080), 3840 x 2160, 4096 x 2160
Ethernet LAN (RJ-45) ports2
Product colorBlack
Product designDigital signage flat panel
Bezel width (bottom)15.5 mm
Panel mounting interface300 x 300 mm
Compatible productsC-tick; CE; FCC Class B; PSB; TÜV GS; UL/C-UL or CSA; VCCI
Operating hours (hours/days)24/7
Sustainability certificatesRoHS
RMS rated power20 W
Power consumption (standby)1 W
Power consumption (typical)135 W
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)20 - 80 %
Cables includedAC, DVI
CertificationC-tick; CE; FCC;' PSB; RoHS; TÜV GS; UL/C-UL CSA; VCCI
Weight and Dimensions IconWeight and Dimensions
Depth66.5 mm
Width920.6 mm
Height532.2 mm
Weight17000 g