Chapter 3 REMOTE UNIT OVER IP FEATURES
3-21 NWA-088654-001 Rev.1.0
94ch3001.fm
SYSTEM SETUP
SYSTEM SETUP
(1) Procedure of Reset Operation
STEP1: Assign all required system data to the CPU blade of Main Unit, including the required data for
Remote Unit.
STEP2: Load all License Activation data to the Main Unit.
For details, refer to License Activation Operation Guide. [For other than North America]
STEP3: Execute the system data backup to the Flash ROM of CPU blade by CMEC Y=6>0: 0.
STEP4: Save the system data of Main Unit by PCPro.
STEP5: Set the SENSE switch of #0 CPU to “E” (Off-line), and push the RESET switch of #0 CPU.
STEP6: Clear the system memory of Remote Unit by CM00>1.
STEP7: Load the system data saved in STEP4 to all Remote Units using PCPro.
STEP8: Assign the Unit numbers for Remote Unit to each CPU blade of Remote Units by CM0B
Y=000>90. Page 3-41
STEP9: Set the SENSE switch of #0 CPU to “1” (on-line), and push the RESET switch of #0 CPU.
STEP10: Confirm that the link between Main Unit and Remote Unit is established.
If not, connect the Main Unit and Remote Unit by LAN.
The required system data is copied to each Remote Unit from the Main Unit, and Remote
Units starts.