90
English ...
Appendices
Mechanical NP-V302X NP-V302W NP-V332X NP-V332W NP-V302H
Installation
Orientation
Desktop/Front, Desktop/Rear, Ceiling/Front, Ceiling/Rear
Dimensions 12.8"(W) x 3.5" (H) X 9.3" (D) / 324 mm (W) x 88 mm (H) x 237 mm (D)
(not including protrusions)
Weight 2.7 kg/6.0lbs 2.8 kg/6.2lbs 2.9 kg/6.4lbs
Environmental
Conditions *8
Operational Temperatures: 41° to 104° (5°C to 40°C) 20% to 80% humidity (non-
condensing)
Storage Temperatures: 14° to 122° F (-10°C to 50°C) 20% to 80% humidity (non-
condensing)
Regulations UL/C-UL Approved (UL 60950-1, CSA 60950-1)
Meets DOC Canada Class B requirements
Meets FCC Class B requirements
Meets AS/NZS CISPR.22 Class B
Meets EMC Directive (EN55022, EN55024, EN61000-3-2, EN61000-3-3)
Meets Low Voltage Directive (EN60950-1, TÜV Approved)
*8 Operational temperatures
- 0 to 2500 feet/760 m in the range of 41° to 104°F (5°to 40°C)
- 2500 feet/760m to 5000 feet/1500 m in the range of 41°to 95°F (5°to 35°C)
- 5000 feet/1500 m to 10000 feet/3000 m in the range of 41°to 86°F (5°to 30°C)
- Set [FAN MODE] to [HIGH ALTITUDE] when using the projector at altitudes
approx. 2500 feet/760 m or higher.