bit6 : Lamp(or Lamp1) error
bit7 : Lamp(or Lamp1) has reached its end of life
DATA02 Error Status (2)
bit0 : Lamp(or Lamp1) has been used beyond its limit
bit1 : Formatter error
bit2 : Lamp2 error
bit3 : None
bit4 : None
bit5 : None
bit6 : None
bit7 : None
DATA03 Error Status (3)
bit0 : None
bit1 : FPGA error
bit2 : Temperature error(Sensor)
bit3 : Lamp(or Lamp1) housing error (!)
bit4 : Lamp(or Lamp1) data error (!)
bit5 : Mirror cover error
bit6 : Lamp2 has reached its end of life
bit7 : Lamp2 has been used beyond its limit
DATA03 Error Status (4)
bit0 : Lamp2 housing error
bit1 : Lamp2 data error
bit2 : High temperature due to dust pile-up
bit3 : A foreign object sensor error
bit4 : Pump error
bit5 : None
bit6 : None
bit7 : None
DATA05 .. 12 Reserved
Response: At the time of a failure
A0H 88H 01H xxH 02H DATA01 DATA02 CKS
(*1) (*2) (*4) (*3)
Supplement:
(!) LT/LT80/HT: "None"
015. POWER ON
**********************************************************************
Function:
This command switches on the main power of the projector.
Command:
02H 00H 00H 00H 00H 02H
Response: At the time of a success
22H 00H 01H xxH 00H CKS
(*1) (*2) (*3)
Response: At the time of a failure
A2H 00H 01H xxH 02H DATA01 DATA02 CKS
(*1) (*2) (*4) (*3)

Other manuals for NEC VT695