EasyManua.ls Logo

Nedap Invexs MND190 - Page 2

Nedap Invexs MND190
4 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2
EN
Quick Install sheet | Invexs 190 Readers Mifare Nedap dual technology mullion readers
Version 8.0
SAM cover
4. Connections
Invexs is not hot-swappable, so when making/changing connections power must be switched
Off.
Colour
Function
Red
Power in (12-30VDC) /
XS modulator (120kHz)
Black
Power Ground / RF Ground
Grey
RS485 A (-)
Violet
RS485 B (+)
Green
Wiegand Data 0 (D0)
White
Wiegand Data 1 (D1)
Yellow
Beep input (BEEP)
Pink
UL LED input (UL*)
Blue
MD LED input (MD*)
Brown
NA LED input (NA*)
Shield / Metal
EM shield (connected to power ground)
Cable shield (wire 11) must be connected to the metal case of the external device
If connected to a 120kHz RF device (AEOS Nedap reader AEpack or XS device) the
power is supplied via the Convexs adapters (AX1014 for AEpacks, AB350 for XS
devices). Existing antenna cabling can then be reused for connecting the Invexs.
On the AX1014 an additional connection between GND (for UL and NA) and
Antenna GND must be made on the AX1014 (Invexs 190 has no separate cable
for this connection).
UL*,NA*, MD* and BEEP are inputs for Open Collector to GND. If the Convexs
adapters are used, the original UL and NA signals are converted to the UL* and NA*.
5. LED Indicators Inside / Backside
There are two LEDs available: Blue for Status (of application), Green for Identification (both
visible behind the SAM cover at the back side)
6. LED Indicators Front
At the front a three colour LED is positioned at the middle of the Invexs
Depending on the used configuration the function of these LEDs can differ:
Green LED: Card is been authorised (UL LED)
Red LED: Card is not authorised (NA LED), controller is stand-by
Blue LED:
Blinks fast: No configuration is available at this Invexs (present Configuration
card or load Configuration first).
Continuously ON: Determined by configuration: E.g. Reader stand-by.
(Blue LED is activated if UL is OFF and NA is more than 1 sec OFF)
R
GND
UL*/NA* / BEEP
ID (green)
Blinking
Card detected
ST: STATUS (blue)
Slow blinking
Application running (operating)
Fast blinking
Downloading or error during loading
2 short flashes
Application present but not active
3 short flashes
No application present

Other manuals for Nedap Invexs MND190

Related product manuals