Quick Install sheet | Invexs 190 Readers Mifare Nedap dual technology mullion readers
9. Tamper Switch
The Invexs 190 is equipped with a tamper switch which can be monitored over the RS485NR
protocol.
10. Beeper Indications
Beeper is also used for indication of loading the configuration:
• High sound beep (‘happy sound’): Configuration is loaded correct, second high sound
beep indicates that this configuration can be used with this Invexs
• Low sound beep (‘unhappy sound’): Configuration is not correct loaded or no
configuration available at start-up
SPECIFICATIONS Invexs 190: MD190 (article no.9948406), MND190 (article no.9948414), MDK190 (article no.9948457),
MNK190 (article no.9948449), MNDK190 (article no.9948465)
Discontinued products: M190 (article no. 9945512), MN190 (article no. 9948392), MK190 (article no. 9948422)
Power Supply:
M(N)(D)190 12 – 30VDC, 60 - 24mA SELV
Consumption:
M(N)(D)K190 12 – 30VDC, 90 - 36mA SELV
Temperature: Operating:-30 – 65°C,
Storage:-30 – 65°C
Communication
RS485 (Encrypted AEOS protocol to APx003, (firmware APx003rs485NR). RS485 plain
Wiegand Data 0 and Data 1 (protocol depending on configuration)
RF Modulator (120 kHz for AX1014 or AB350)
Inputs:
Beeper (Beep ON / OFF, controlled by application) and Open collector to GND, max 20mA
UL*, NA*, MD* LED Open collector to GND, max 20mA
UL (green) NA (red) ,MD (blue)
Antennas
(internal):
Antenna 1: 120 kHz, Nedap XS compatible (PM and AM cards). Detection distance UniXS card: 8 cm
Antenna 2: 13,56 MHz, Mifare compatible Detection distance Mifare card: 4 cm
Mifare EV1 card: 2 cm
CABLE SPECIFICATIONS
10 wire shielded cable of approx. 3 meters length included (pig tail). Extensions can be made:
2 x 2 x 0,25mm² shielded, max cable length: 1000 meter, cable capacity <= 100pF/meter
UL/GND/NA:
3 x 0,25mm², max cable length: 50 meter
XS MOD / GND:
Coax RG58U, max cable length: 50 meter
Or 5 x 0,25mm² shielded, max cable length: 50 meter, cable capacity <= 100pF/meter
4 x 0,25mm² shielded (excl. LEDs), max cable length: 150 meter, depending on receiving device
MORE INFORMATION: Contact your local Nedap supplier or check our website www.nedapsecurity.com