6
3 Installation instructions
The SMART DEAC electronics unit must be powered with a NEC class2 type power source like the NEDAP
AC/DCpoweradapter100~240Vac/12VdcNEDAPpartnumber9651802.
Always place the unit near a power outlet (less than 1 meter / 3.3 feet ), the power outlet should be easily
accessible, also after installation.
All the outputs from the SMART DEAC are NEC class2 outputs, output voltages will be 12Vdc or less.
The inputs may only be connected to class2 powered system.
TheSMARTDEACmustbemountedonasolid,nonammablesurface,usingallmountingholesandproper
mounting material, according to local regulations.
All wiring should be done according to local regulations.
External LED
An external LED can be connected to the connector pins marked LED + and -. We recommend the use of an
ULrecognizedLEDliketheAPEMredpanelmountindicatorledtypeQ14F1CXXR02.
(V_forward 1,6v +/-10% and I_forward max. 20mA)
The LED output is current limited and short-circuit protected.