8
5 SpecicationsSMARTDEAC
Enviromental
Description
Material Construction Aluminium
Protection Class IP20
Min. Typical Max. Condition
Operating frequency 7.5MHz 8.2MHz 8.8MHz
Operational temperature 0 ºC / 32 °F 40 ºC / 104 °F
Storage temperature -10 ºC / 14 °F +70ºC/158°F
Relative Humidity 20 % 90 % non-condensing
Operating Distance 0.3 m / 12” Tag-dependant
InputRequirementsandelectricalspecications
Description
Min. Typical Max. Condition
Input Voltage 90 VAC 100-240 264 VAC FullRange;50/60Hz
Input Current 0.35 A - 0.7 A 264 VAC - 90 VAC
Line Frequency 47Hz 50-60Hz 63Hz -
Operation Voltage
Power 3 W 230VAC50Hz
Regulations
Safety approvals of the Power Adapter
• cULus according to UL/CSA 60950-1
• CB according to IEC60950-1
• TUV EN60950-1 (2006)
• NEC Class 2
• CE Europe according to EN300330
• Japan PSE
Telecom system approval
• Canada IC according to RSS210 IC ID:1444A-SMARTDEAC
• US according to FCC Part 15 FCC ID:CGDSMARTDEAC
• CE according to EN300330
• Japan pending
In compliance with Human exposure assessment according to:
• EN62369-1 and EN50364
• ICNIRP Guidelines
• IEEE C95.1
• RSS102
• ARIBSTD-38
• IEC62369-1
Electromagnetic compatibility
• EN301489(EmissionaccordingtoEN55022)
• IEC 61000-6-2
• IEC 61000-6-3
• CISPR 22