uPASS Reach | quick reference guide
5/
Relay output
The relay output is automatically activated upon identification of a tag.
In OSDP operation, the relay output is set with command OSDP_OUT output #0.
Relay contact normally closed
Relay contact normally open
Read disable input
The reading of the uPASS Reach can (optionally) be disabled with the RDIS input. This input is commonly used in
combination with a sensor (e.g. inductive loop) that detects the presence of a vehicle. A potential-free contact (relay)
should be used to activate this input and disable the reading.
Connections
Internal 5V source for read disable input
Warning: using an external voltage supply can damage the unit!
DIP-switches
SW2 (1-8): TRANSIT compatible mode settings. Refer to the TRANSIT firmware manual for details.
SW1 (1-4): Hardware settings. Described below.
SW4 (1-4): Hardware settings. Only uPASS Reach model 2020. Described below.
-XS formatted tags
* Default all switches ON