uPASS Reach | quick reference guide
5/
6
Relay output
The relay output is automatically activated upon identification of a tag.
In OSDP operation, the relay output is set with command OSDP_OUT output #0.
Connections
Contact ratings
K5 NC
Relay contact normally closed
Max. switching current
2 A
K5 COM
Relay contact common
Max. switching voltage
24 VDC
K5 NO
Relay contact normally open
Max. switching power
50 W
Read disable input
The reading of the uPASS Reach can (optionally) be disabled with the RDIS input. This input is commonly used in
combination with a sensor (e.g. inductive loop) that detects the presence of a vehicle. A potential-free contact (relay)
should be used to activate this input and disable the reading.
Connections
K3 RDIS
Read disable input
K5 5V
Internal 5V source for read disable input
Warning: using an external voltage supply can damage the unit!
DIP-switches
SW2 (1-8): TRANSIT compatible mode settings. Refer to the TRANSIT firmware manual for details.
SW1 (1-4): Hardware settings. Described below.
SW4 (1-4): Hardware settings. Only uPASS Reach model 2020. Described below.
uPASS Standard mode (*)
ON
1
2
3
4
SW1
ON
1
2
3
4
SW4
TRANSIT compatible mode
ON
1
2
3
4
SW1
ON
1
2
3
4
SW4
Requires NEDAP
-XS formatted tags
Buzzer enabled (*)
ON
1
2
3
4
SW1
ON
1
2
3
4
SW4
Buzzer disabled
ON
1
2
3
4
SW1
ON
1
2
3
4
SW4
RS232 (*)
ON
1
2
3
4
SW1
ON
1
2
3
4
SW4
RS422
ON
1
2
3
4
SW1
ON
1
2
3
4
SW4
RS485 (terminated)
ON
1
2
3
4
SW1
ON
1
2
3
4
SW4
RS485 (not terminated)
ON
1
2
3
4
SW1
ON
1
2
3
4
SW4
* Default all switches ON