6
LED indications
A number of LED’s indicate the current status of the uPASS Reach reader.
UERR
UREAD
UTAG
USTS
RESET
TEST
The table below describes the function of each LED.
Led
Description
RX
LEVEL
LED bar indicating the received tag signal strength. This LED bar may also
indicate the presence of radio interference. In case of interference, try
switching to a different frequency.
RDIS
Read Disable LED. On while reading disabled.
IN1
Input 1 status. On when input 1 contact is closed.
TXD
Transmit serial data.
RXD
Receive serial data.
ID
TRANSIT compatible processor ID LED. Blinks when a tag is identified.
STS
TRANSIT compatible processor status LED.
SQ-ACT
Squelch active. When squelch is enabled and the transponder return
signal below threshold level.
DC-HI
Power supply voltage too high.
DC-LO
Power supply voltage too low.
DC-FAIL
Internal supply voltage failure.
T-CRIT
Temperature critically high.
PLL UL
PLL unlocked. Error indication only. No direct hardware action
implemented.
USTS
UHF processor status LED. Should be slowly blinking. On when bootloader
invoked.
UTAG
Tag found. RN16 received.
UREAD
Tag data read complete. On when bootloader invoked.
UERR
Error during tag identification.