FilterCart W3
1 Disconnect the mains connection cable.
2 Unlock the eccentric locks and remove the filter
casing.
3 Use the plastic bag which comes with the new fil-
ter cartridge and pull it over the used cartridge.
Fold the plastic bag under the cartridge.
4 Use a duster to wipe off the filter cartridge con-
tact surfaces in the FilterCart W3. Put the duster in
the plastic bag with the filter cartridge and close
the bag with the band supplied.
5 Handle the used filter cartridge according to the
relevant regulations for the substances that have
been collected.
6 Check that the pressure drop hose (from the con-
trol board) not is damaged and is fitted properly.
7 Check that the new filter cartridge is not damaged.
Also, check that the seal fitted on the underside
of the cartridge is not damaged. Then fit the cart-
ridge on the FilterCart W3.
8 Refit the filter casing. Make sure the eccentric
locks tighten the filter casing properly.
A: Increasing the locking power.
B: Decreasing the locking power.
6.2 Changing the HEPA-filter (access-
ory)
See Figure8. If the FilterCart W3 has been supplied
with a HEPA-filter, this is to be changed at the same
time as the main filter cartridge is changed.
WARNING!Risk of personal injury
Use necessary personal safety equipment
when changing the HEPA-filter.
Change the HEPA-filter cartridge in the following way:
1 Disconnect the mains connection cable.
2 Unscrew the top cover.
3 Remove the used HEPA-filter and put it in the
plastic bag which comes with the new HEPA filter.
Close the plastic bag with the band supplied.
4 Handle the used HEPA-filter according to the rel-
evant regulations for the substances that have
been collected.
5 Check that the new HEPA-filter, item A, is not
damaged.
NOTE!
The filter surface must not be touched.
6 Verify that the UP-arrow, item B, is pointing up-
wards. Handle the HEPA-filter very carefully and
fit it in the FilterCart W3. Ensure it is fitted in the
correct position and that the seal is downwards.
Check that the seal not is damaged.
7 Refit the top cover. Fasten it securely.
7Spare Parts
CAUTION!Risk of equipment damage
Use only N$e$d$e$r$m$a$n$ original spare parts and ac-
cessories.
Contact your nearest authorized distributor or
N$e$d$e$r$m$a$n$ for advice on technical service or
if you require help with spare parts. See also
w$w$w$.$n$e$d$e$r$m$a$n$.$c$o$m$.
7.1Ordering spare parts
When ordering spare parts always state the following:
The part number and control number (see the
product identification plate).
Detail number and name of the spare part (see
w$w$w$.$n$e$d$e$r$m$a$n$.$c$o$m$/$e$n$/$s$e$r$v$i$c$e$/$s$p$a$r$e$-$p$a$r$t$-
$s$e$a$r$c$h$).
Quantity of the parts required.
8Accessories
HEPA-filter H13, 7.5 m
2
(81 ft
2
) high-efficiency fi-
nal filter, class H13.
Spark protection, for mounting in the hood. To re-
duce the risk of fire.
9Recycling
The product has been designed for component mater-
ials to be recycled. Different material types must be
handled according to relevant local regulations. Con-
tact the distributor or$N$e$d$e$r$m$a$n$ if uncertainties arise
when scrapping the product at the end of its service
life.
EN
17

Table of Contents

Other manuals for Nederman FilterCart W3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nederman FilterCart W3 and is the answer not in the manual?

Nederman FilterCart W3 Specifications

General IconGeneral
BrandNederman
ModelFilterCart W3
CategoryWater Filtration Systems
LanguageEnglish

Related product manuals