Neotherm Basis AB 4071-6 - User Manual

Default Icon
72 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
FIN
SWE
NOR
DK
GB
DE
Basis AB 4071-12
INHALT
Übersicht .....................................2
Produktbeschreibung ..............2
Lieferumfang ...........................2
Optionales Zubehör ...............2
Systembeschreibung ...............3
Infosymbole .............................3
Das System Funk 868 MHz ......3
Heizen/Kühlen-Funktion .........4
Sicherheit ....................................4
Sicherheitshinweise .................4
Montageanleitung .....................5
Montage auf Tragschiene .......5
Anschluss der Antriebe ...........5
Betriebsanleitung .......................6
Inbetriebnahme .......................6
Energiesparprogramme ..........6
Heizzonen zuordnen ...............7
Funktionstests ..........................7
Installation Regler Funk ..........8
Regelbetrieb ............................8
Signalisierung der Heizzonen (HZ) .....9
Löschen aller Einstellungen ....9
Austauschen der Sicherung ....9
Technische Daten .....................10
Technische Daten ...................10
Störbeseitigung .....................11
Anhang .....................................12
Systemübersicht .....................12
Urheberrecht .........................12
Basis AB 4071-6
HANDBUCH
Alpha-Basis Funk 868 MHz
8-D51-53-017 Rev 1.0

Table of Contents

Questions and Answers

  • K
    kimberlypowellAug 2, 2025
    What to do if the Neotherm Control Unit fuse is defective but the indicator lights up?
    • J
      Joshua ShepherdAug 3, 2025
      If the fuse is defective but the indicator lights up, it could be due to a short circuit in the individual room control. To resolve this, shut off the unit, disconnect the actuators (observing the correct order), and insert a new fuse. If the fuse no longer trips, inspect the actuators for damage and the valves for leaks, replacing any defective parts as needed. If the fuse trips repeatedly, examine the connected thermostats for faulty wiring.
  • M
    Molly DownsAug 16, 2025
    Why is the operation indicator not lighting up on my Neotherm Control Unit?
    • M
      Mark RodriguezAug 16, 2025
      If the operation indicator on your Neotherm Control Unit is not lighting up, there are a couple of potential causes. First, there may be a wiring error in the main connection, so check the wiring. Second, there might be no main voltage present, so check the supply circuit fuse.

Summary

Overview

Product description

Details the intelligent connection unit for single room control of surface heating/cooling systems.

Scope of supply

Lists the components included in the wireless system package.

Optional accessories (not included)

Describes optional items like the External Receiver and Wireless Inspector.

System description

The Wireless System 868 MHz

Explains the system's components and capabilities for heating/cooling control.

Information Symbols

Caution, danger!

Symbol indicating a caution or danger.

Shut down the system!

Symbol indicating the need to shut down the system.

Tip!

Symbol indicating a helpful tip for installation.

Heating;Cooling Function

Function Cooling blocking

How to deactivate or block individual zones from active cooling operation.

Operating procedure

Step-by-step guide for adjusting cooling block settings.

System Reset

Procedure to reset the equipment to its delivery state.

Safety

Intended Use and Hazards

Covers intended applications, potential dangers, and necessary precautions.

Safety Notes and Procedures

Provides general safety notes, installer qualifications, and emergency shutdown.

Installation Instructions

Installation on Mounting

Guidance on mounting the Basis Wireless unit.

Installation of Actuators

Instructions for connecting Actuators to the Basis Wireless unit.

Plug;clamp connections

Details on suitable wire types and stripping for connections.

Operating Instructions

Start-up

Steps for initial power-up and system readiness check.

Energy Saving Programs

Configuration of heating programs using the Timer Module.

Arrangement for 6 heating zones

Diagram for assigning rooms to energy saving programs for 6 zones.

Arrangement for 12 heating zones

Diagram for assigning rooms to energy saving programs for 12 zones.

Allocating Heating Zones

Zone Assignment Procedure

Step-by-step guide for assigning wireless thermostats to heating zones.

Functional Tests

Radio Transmission Testing

Procedure for testing radio communication between thermostat and unit.

Wireless Thermostat Installation

Radio transmission

Process of assigning thermostats and the start of control operation.

Control Operation

Function indication of the heating zones

How heating zone LEDs indicate status, switching, and errors.

Temperature Setback Mode

How the system adjusts room temperature in setback mode.

Signalling of the Heating Zones (HZ)

Zone Signalling Status

Explains LED indications for normal, low battery, weak signal, emergency, and programming modes.

Deleting All Settings

Deletion Process

Procedure to reset all allocations and return to delivery state.

Replacing the Fuse

Fuse Replacement Procedure

Instructions for replacing a blown fuse, requiring specialist intervention.

Technical Data

Basis Wireless Specifications

Technical details for the Basis unit, including properties and system types.

Component Data

Details on wire types, fuses, and Alpha-System Wireless parameters.

Troubleshooting

Malfunction

Table listing malfunctions, causes, and elimination steps.

Emergency Operation

System behavior during prolonged lack of thermostat signal.

Valve protection

Mechanism to prevent valve clogging outside the heating season.

What happens after a power failure?

How the system retains programs and handles restarts.

Appendix

System Overview

Table showing system components and their voltage/frequency compatibility.

Copyright

Copyright notice for the manual.

Neotherm Basis AB 4071-6 Specifications

General IconGeneral
BrandNeotherm
ModelBasis AB 4071-6
CategoryControl Unit
LanguageEnglish