NMC-DC
INSTALLATION MANUAL
Page: of 109 pagesRevision: 01 IDoc. Name: NMC-DC I Installation Manual
Crop Management Technologies
Sensor type Description
pH sensor pH = 0 A/D = 205
pH = 7.0 A/D = 615
pH = 14.0 A/D = 1023
EC sensor EC = 0 A/D = 205
EC = 2.0 A/D = 370
EC = 10.0 A/D = 1024
Humidity sensor RH% = 0 A/D = 0
RH% = 50 A/D = 308
RH% = 100 A/D = 620
Temp sensor
T°C = 0 A/D = 768
T°C = 25 A/D = 489
T°C = 50 A/D = 250
Table 6.4
42