EasyManua.ls Logo

Netafim TECHLINE CV User Manual

Netafim TECHLINE CV
42 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
M-TCVDG 5/04
Techline
®
CV Design Guide
NETAFIM USA
5470 E. Home Ave. • Fresno, CA 93727
888.638.2346 • 559.453.6800
FAX 800.695.4753
www.netafimusa.com
Subsurface or On-Surface
Pressure Compensating Dripperline
with Check Valve

Table of Contents

Other manuals for Netafim TECHLINE CV

Question and Answer IconNeed help?

Do you have a question about the Netafim TECHLINE CV and is the answer not in the manual?

Netafim TECHLINE CV Specifications

General IconGeneral
TypePressure Compensating Dripline
Filtration Requirements120 mesh
MaterialPolyethylene
ApplicationSubsurface and On-surface Irrigation
Emitter TypePressure Compensating
Check ValveYes, built-in
Tubing Diameter16 mm, 20 mm
Emitter Spacing12, 18, 24, 36 inches
Wall Thickness1.1 mm
Clog ResistanceHigh
Connection TypeBarbed or Compression

Summary

Introduction to Techline CV

Overview of Netafim and Techline CV

General overview of Netafim's role and Techline CV benefits in low volume irrigation.

Design Criteria for Irrigation Systems

Site Survey and Analysis

Process of evaluating the irrigation site, including soil type and plant materials.

Point of Connection Details

Determining water source type, pressure, and volume available for the system.

Basic Design Steps for Techline CV

When to Use Techline CV

Guidance on applications where Techline CV provides an even water pattern, similar to sprinklers.

Choosing the Correct Techline CV

How to select the correct Techline CV based on plant type, soil, and dripper spacing.

Types of Techline CV Layouts

Description of the recommended 'GRID' and 'LITE' layout methods for Techline CV.

Common Elements of Layouts

Common principles for both GRID and LITE layouts, focusing on even spacing and loop flow.

Basic Grid Layout Configuration

Details on header placement, material, sizing, and lateral spacing for grid layouts.

Basic Lite Layout Configuration

Instructions for the on-surface LITE layout, including water splitting and lateral placement.

Calculating Row Spacing

Method for determining uniform row spacing based on area dimensions and setbacks.

Maximum Lateral Lengths

Maximum allowable lateral lengths and required operating pressures based on dripper spacing.

Center Feed Grid Layouts

Advantages and application of center-fed grid layouts for increased lateral length and even flow.

Other Grid Layout Considerations

Rules for branching and joining Techline CV laterals and creating subheaders.

Zone Water Requirements Calculation

Method for calculating total zone flow based on dripper spacing, flow rate, and total length.

Required Fittings

Overview of necessary fittings for connecting Techline CV in GRID and LITE layouts.

Staple Usage Guidelines

Guidelines for using Techline CV staples to secure tubing on various soil types and at fittings.

Line Flushing Valve Operation

Purpose and operation of line flushing valves for cleaning dripperlines during zone activation.

Automatic Line Flushing Valve Installation

Placement and installation of automatic line flushing valves to ensure zone cleansing.

Manual Flushing Valve Alternatives

Alternative methods using shut-off valves or line ends for manual flushing.

Air/Vacuum Relief Valve Function

Function and placement of Air/Vacuum Relief Valves to manage air and vacuum in the system.

Filtration Requirements

Importance of filtration for protecting dripper orifices and recommendations for mesh size.

Pressure Regulating Valve (PRV) Selection

Selection criteria and installation of PRVs to maintain optimal operating pressure for Techline CV.

Low Flow Control Zone Kits

Components and flow range for low volume control zone kits (0.25-4.4 GPM).

High Flow Control Zone Kits

Components and flow range for high flow volume control zone kits (3.5-17.6 GPM).

Slopes and Berm Irrigation

Guidelines for installing Techline CV on slopes, including row spacing adjustments.

Techline Check Valve (TLCV) Specifications

Specifications and function of the TLCV inline check valve for managing water columns.

Irrigation for Trees

Recommendations for irrigating trees, ensuring adequate water to rootballs and surrounding soil.

Pressure and Flow Checks

Methods for testing and recording system pressure and flow to ensure proper operation.

Calculating Precipitation Rates

Formulas and tables for calculating the application rate of Techline CV systems.

Techline CV in Turfgrass Applications

Techline CV in Turfgrass

Background on Netafim's successful use of Techline CV in various turfgrass applications.

Why Use Techline CV in Turf

Benefits and applications of Techline CV in turf for areas like long/narrow zones and athletic fields.

Tips for Newly-Sodded Lawns

Specific advice for installing and maintaining Techline CV in new sod, including burial depth and watering.

Special Applications and Tips

Parking Lot Islands Irrigation

Design considerations for irrigating parking lot islands, including zone grouping and flushing points.

Electrical Grounding Methods

Methods for ensuring effective electrical grounding using Techline CV and copper wire.

Above and Below Grade Installation

Options for installing Techline CV on the surface, with mulch, or buried below grade.

Techline CV Winterizing Instructions

Manual Winterization Procedure

Steps for draining the system manually to prevent freeze damage.

Compressed Air Winterization Procedure

Procedure for using compressed air to clear water from the system for winterization.

Technical Data for Techline CV

Applications of Techline CV

List of common applications for Techline CV dripperline in various environments.

Techline CV General Specifications

Technical details including flow rates, spacing, pressure compensation, and tubing dimensions.

Techline CV Features and Benefits

Key advantages of Techline CV, such as check valves, root barrier, and pressure compensation.

Techline CV Dripper Exploded View

Detailed diagram showing the internal components of the Techline CV dripper.

Design Formulas for Techline CV

Mathematical formulas for calculating dripperline length, application rate, flow, and total zone water demand.

Techline CV Specifying Information

Specifying information for Techline CV, including model numbers for dripperline and ordering codes.

Techline CV Application Rate Tables

Tables detailing application rates based on dripper flow, spacing, and row spacing.

Techline CV General Guidelines

General guidelines covering dripper flow, spacing, burial depth, and application rates for various soils.

Techline CV Maximum Lateral Length

Chart showing maximum lateral lengths based on inlet pressure and dripper spacing.

Techline CV Flow Rates per 100 Feet

Table providing flow rates per 100 feet for different dripper spacings and flow rates.

Disc Filter Sizing Recommendations

Recommendations for selecting the appropriate disc filter size and mesh based on flow rates.

Techline CV with Techfilter System

Information on the Techfilter system, its function against root intrusion, and Triflurex technology.

Techfilter Installation and Mounting

Guidance on installing the Techfilter to ensure easy maintenance and avoid direct sunlight.

Techfilter Use and Replacement

Recommendations for the effective use and replacement schedule for Techfilter cartridges.

Techfilter Specifying Information

Details on how to specify Techfilter models based on filter size and Techline CV requirements.

Techfilter Model Number Descriptions

Table correlating Techfilter model numbers with specific Techline CV configurations.

Techfilter Model Number Descriptions (Continued)

Continued model number descriptions for Techfilter and Techline CV combinations.

Techline CV End Feed Layout

Diagram illustrating the end-feed layout configuration for Techline CV systems.

Techline CV Center Feed Layout

Diagram illustrating the center-feed layout configuration for Techline CV systems.

Installation Checklist

Fittings Overview

Notes

Related product manuals