EasyManua.ls Logo

Netafim SPINNET

Netafim SPINNET
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
V 001.01 - 2018
SPINNET
SD
VIBRONET
COOLNET PRO
MISTNET
SPINNET
MICRO-SPRINKLERS/EMITTERS
UPSIDE-DOWN
HANDBOOK

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Netafim SPINNET and is the answer not in the manual?

Netafim SPINNET Specifications

General IconGeneral
BrandNetafim
ModelSPINNET
CategoryIrrigation System
LanguageEnglish

Summary

INTRODUCTION

Objectives of this document

Presents basic concepts of upside down micro-sprinkler/emitter systems for protected crops.

Safety instructions

Local safety regulations must be applied when installing, operating, and troubleshooting.

MICRO-SPRINKLEREMITTER SELECTION

Introduction

Netafim micro-sprinklers/emitters are ideal for irrigation, cooling, and humidity enhancing in protected crops.

Uses

Application of micro-sprinklers/emitters for protected crops like greenhouses and nurseries.

Applications: Irrigation

Discusses using micro-sprinklers for full coverage irrigation in protected crops.

Applications: Germination

Gentle irrigation for seed germination, requiring uniform water distribution.

Applications: Cooling

Evaporative cooling using fine water droplets to cool air in enclosed structures.

Applications: Rooting

Creating a moist air volume to facilitate plant root growth.

Applications: Humidity increasing

Increasing air humidity in structures, especially during heating periods.

Terms and concepts

Key terms for selecting micro-sprinkler systems: precipitation rate, uniformity, head loss.

Water distribution uniformity

Importance of even water distribution for crop yield and quality. Testing methods.

Christiansen Coefficient of Uniformity (%CU)

Method for measuring uniformity, represented as a percentage of deviation from the average.

Distribution uniformity (%DU)

Method comparing driest 25% of area to average application for uniformity assessment.

Scheduling Coefficient (SC)

Run-time multiplier representing time to over-irrigate driest parts for average coverage.

Maximum length of distribution pipe

Factors influencing maximum pipe length to maintain pressure and uniformity.

Head loss in the hanging micro-tube and accessories

Factors defining head loss in micro-tubes and accessories.

micro-sprinkleremitter water trajectory

Elevations, heights, and distances related to emitter water trajectory.

Selecting a micro-sprinkleremitter

Criteria for selecting emitters based on crop needs, soil, and grower objectives.

MICRO-SPRINKLERSEMITTERS ASSORTMENT

Drip-less and shadow-less micro-sprinklersemitters

Benefits of bridgeless emitters for drip-less and shadow-less operation.

Durability and low maintenance

Materials and construction ensuring durability and resistance to chemicals.

Compliance with international standard requirements

Design and testing according to standard requirements.

Reliable anti-drain (AD) valves

Function of AD valves to prevent pipe drainage and ensure simultaneous emitter start/stop.

SpinNet

Description of SpinNet™ bridgeless micro-sprinklers for upside-down stands.

Filtration

Filtration methods based on water dirt particle type and concentration.

Features and benefits

Drip-less, shadow-less, interchangeable components, acid resistance for SpinNet™.

Performance

Flow rate calculation and wetted diameter data for SpinNet™.

Water trajectory

Trajectory height and distance from emitter head for SpinNet™ swivels.

Distribution uniformity at different spacings - rectangular pattern

Precipitation rates for SpinNet™ at various spacings and nozzles.

Head loss

Head loss (bar) in the emitter stand micro-tube and AD valve for SpinNet™.

SpinNet SD

Description of SpinNet™ SD micro-sprinklers for irrigated strips in tunnels.

Filtration

Filtration methods for SpinNet™ SD based on water quality.

Features and benefits

Drip-less, shadow-less operation and acid resistance for SpinNet™ SD.

Performance

Flow rate calculation and wetted diameter for SpinNet™ SD.

Water trajectory

Trajectory height and distance from emitter head for SpinNet™ SD swivels.

Distribution uniformity at different area widths

CU% and PR for SpinNet™ SD at various widths and spacings.

Head loss

Head loss in micro-tube and AD valve for SpinNet™ SD.

A particular case

Solutions for irrigating tunnels/greenhouses wider than 8-12 meters with two pipes.

Particular case - distribution uniformity

Full coverage and two parallel strips data for SpinNet™ and SpinNet™ SD.

VibroNet

Description of VibroNet™ micro-emitters with vibrating axle for maximum uniformity.

Performance

Flow rate calculation, wetted diameter, trajectory, and head loss for VibroNet™.

CoolNet Pro

Description of CoolNet Pro™ mister for cooling, rooting, and humidity.

Three different configurations

Cross, 'T', and single body configurations for CoolNet Pro™.

Necessary terms

Definitions of Fog and Fogger in misting systems.

Mister vs. Fogger

Comparison of CoolNet Pro™ mister performance against 'Fogger' products.

Performance

Flow rate calculation, water trajectory, and head loss for CoolNet Pro™.

Definition of the different applications and Installation recommendations

Guidelines for evaporative cooling using misters.

Installation recommendations for cooling

Specific installation advice for CoolNet Pro™ cross and 'T' misters for cooling.

Rooting

Recommendations for rooting applications using CoolNet Pro™ mister.

Humidity increasing

Recommendations for increasing humidity using CoolNet Pro™ mister.

MistNet

Description of MistNet™ mister for under plant cooling and humidifying.

Specifications

Specs for MistNet™ models, filtration, and working pressures.

Filtration

Filtration recommendations for MistNet™ systems.

Features and benefits

Interchangeable components, acid resistance for MistNet™.

Performance

Flow rate calculation, water trajectory for MistNet™.

ACCESSORIES AND COMPLEMENTARY PRODUCTS

Introduction

Accessories and complementary products designed to improve UD micro-sprinkler/emitter system performance.

Anti-drain (AD) valve

Function of AD valves to prevent pipe drainage and ensure simultaneous emitter start/stop.

AD valve models and performance

Models, opening/shut-off pressures, and head loss for AD valves.

Stabilizer

Function of stabilizer to maintain emitter verticality and improve stability.

PE flexible tube

Recommendation for using flexible micro-tubes with stabilizers for proper emitter alignment.

Top connectors

Partial listing of connectors for attaching hanging stands to distribution pipes.

Accessory connection

Methods for connecting hanging stand top connectors to distribution pipes.

APPENDIX

Max. distribution pipe length with 10% flow variation

Tables showing max pipe length for various PE pipe sizes and slopes.

WARRANTY

Limited warranty

Warranty terms and conditions for Netafim products.

Related product manuals