EasyManua.ls Logo

NetApp ASA A150 - Page 68

NetApp ASA A150
87 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
The failed drive appears in the list of failed drives. If it does not, you should wait, and then run the
command again.
Depending on the drive type and capacity, it can take up to several hours for the drive to
appear in the list of failed drives.
Determine whether SED authentication is enabled.
How you replace the disk depends on how the disk drive is being used. If SED authentication is enabled,
you must use the SED replacement instructions in the ONTAP 9 NetApp Encryption Power Guide. These
Instructions describe additional steps you must perform before and after replacing an SED.
Make sure the replacement drive is supported by your platform. See the NetApp Hardware Universe.
Make sure all other components in the system are functioning properly; if not, you must contact technical
support.
About this task
Drive firmware is automatically updated (nondisruptively) on new drives that have non current firmware
versions.
When replacing several disk drives, you must wait one minute between the removal of each failed disk drive
and the insertion of the replacement disk drive to allow the storage system to recognize the existence of each
new disk.
Procedure
Replace the failed drive by selecting the option appropriate to the drives that your platform supports.
66

Related product manuals