6. Verify that you bypassed the disk shelves you are removing and reestablished the path A (IOM A) stack
connections correctly:
storage disk show -port
For HA pair configurations, you run this command from the clustershell of either controller. It might take up
to a minute for the system to complete discovery.
The first two lines of output show disk drives with connectivity through both path A and path B. The last two
lines of output show disk drives with connectivity through a single-path, path B.
cluster::> storage show disk -port
PRIMARY PORT SECONDARY PORT TYPE SHELF BAY
-------- ---- --------- ---- ---- ----- ---
1.20.0 A node1:6a.20.0 B SAS 20 0
1.20.1 A node1:6a.20.1 B SAS 20 1
1.21.0 B - - SAS 21 0
1.21.1 B - - SAS 21 1
...
7.
The next step depends on the
storage disk show -port command output:
39