You can also find information about the failed fan canister in the Details area of the Recovery Guru, or you
can review the Event Log under Support and filter by Component Type.
3. From the back of the storage array, look at the Attention LEDs to locate the fan canister you need to
remove.
You must replace the fan canister that has its Attention LED on.
(1) Attention LED. If this LED displays as Solid amber, then the fan has a fault.
Step 2: Remove failed fan canister and install new one
Remove a failed fan canister so you can replace it with a new one.
If you do not turn off the power to your storage array, ensure that you remove and replace the
fan canister within 30 minutes to prevent the system from overheating.