Do you have a question about the NI 9229 and is the answer not in the manual?
Lists and describes documents related to NI 9229/9239 and NI-DAQmx software.
Lists the recommended equipment for performance verification and adjustment procedures.
Specifies the required setup and environmental conditions for accurate measurements.
Outlines the steps required to set up the NI 9229/9239 for calibration.
Describes procedures to verify the performance of the NI 9229/9239.
Procedure to determine the As-Found status of the NI 9229/9239 accuracy.
Procedure to determine the As-Found status of NI 9229/9239 channel-to-channel gain.
Procedure to determine the As-Found status of NI 9229/9239 channel-to-channel phase.
Describes the sequence of operations required to adjust the NI 9229/9239.
Procedure to adjust the accuracy performance of the NI 9229/9239.
Details the process for updating the NI 9229/9239 internal calibration memory.
Repeat the Verification section to determine the As-Left status of the device.
Lists calibration specifications valid under specific environmental and setup conditions.
Provides resources for technical support, repairs, and product registration.
Lists and describes documents related to NI 9229/9239 and NI-DAQmx software.
Lists the recommended equipment for performance verification and adjustment procedures.
Specifies the required setup and environmental conditions for accurate measurements.
Outlines the steps required to set up the NI 9229/9239 for calibration.
Describes procedures to verify the performance of the NI 9229/9239.
Procedure to determine the As-Found status of the NI 9229/9239 accuracy.
Procedure to determine the As-Found status of NI 9229/9239 channel-to-channel gain.
Procedure to determine the As-Found status of NI 9229/9239 channel-to-channel phase.
Describes the sequence of operations required to adjust the NI 9229/9239.
Procedure to adjust the accuracy performance of the NI 9229/9239.
Details the process for updating the NI 9229/9239 internal calibration memory.
Repeat the Verification section to determine the As-Left status of the device.
Lists calibration specifications valid under specific environmental and setup conditions.
Provides resources for technical support, repairs, and product registration.
The NI 9229/9239 are 4-channel, 24-bit simultaneous, channel-to-channel isolated analog input modules, designed to handle voltage inputs of ±60 V (NI 9229) or ±10 V (NI 9239). These modules are integral components for data acquisition systems, particularly when high-precision, isolated measurements are required. They are compatible with NI cDAQ-9174/9178 USB Chassis and are designed to work seamlessly within the National Instruments ecosystem, leveraging NI-DAQmx driver software for configuration and operation.
The primary function of the NI 9229/9239 modules is to acquire analog voltage signals with high resolution and accuracy. Their 24-bit resolution allows for very fine measurement granularity, making them suitable for applications demanding precise data capture. The simultaneous sampling capability across all four channels ensures that all measurements are taken at the exact same instant, which is crucial for analyzing correlated signals without phase distortion. Channel-to-channel isolation provides electrical separation between individual input channels and the system ground, preventing ground loops and common-mode noise from affecting measurements, thereby enhancing signal integrity and safety. This isolation is particularly beneficial in industrial environments where large common-mode voltages or noisy signals are prevalent. The modules support differential input configurations, which further improves noise rejection by measuring the voltage difference between two points, effectively canceling out common-mode noise present on both lines.
The NI 9229/9239 modules are designed for ease of integration into existing or new test and measurement systems.
Maintaining the accuracy and performance of the NI 9229/9239 modules involves regular calibration and adherence to specified environmental conditions.