Connecting to main
product
CONNECTING TO THE HEAT PUMP
ERS S10 contains an accessory board (AA5) that con-
nects directly to the main product’s PCB (terminal block
AA2-X30).
The communication cable (W102) is connected to the
accessory board (AA5) from the factory.
If more accessories are to be connected, or are already
installed, the boards are connected in series.
Because there can be different connections for accessor-
ies with accessory board (AA5), you should always read
the instructions in the manual for the accessory that is
to be installed.
B
A
GND
+12V
AA2-X30
1 2 3 4
AA5-X4
1
2
3
4
5
6
7
8
A
B
GND
A
B
GND
AA5-X4
1
2
3
4
5
6
7
8
A
B
GND
A
B
GND
Main product
Accessory 1
Accessory 2
The terminal block (AA2-X30) is upright on S1155.
CONNECTING TO CONTROL MODULE
ERS S10 contains an accessory board (AA5) that con-
nects directly to the control module on its joint board
(terminal block AA100-X9).
The communication cable (W102) is connected to the
accessory board (AA5) from the factory.
If more accessories are to be connected, or are already
installed, the boards are connected in series.
Because there can be different connections for accessor-
ies with accessory board (AA5), you should always read
the instructions in the manual for the accessory that is
to be installed.
+12V
GND
B
A
AA100-X9
7
8
9
10
11
12
AA5-X4
1
2
3
4
5
6
7
8
A
B
GND
A
B
GND
AA5-X4
1
2
3
4
5
6
7
8
A
B
GND
A
B
GND
Accessory 1
Accessory 2
SMO S40