Energy labelling
NIBESupplier
ERS S10-400Model
Average: -37.5
Cold: -75.0
Warm: -13.4
kWh/(m
2
year)
Specific energy consumption (SEC)
A
Energy efficiency class
RVU, BidirectionalDeclared typology
Variable speed driveType of drive
RecuperativeType of heat recovery system
86Thermal efficiency of heat recovery
394m
3
/hMaximum air flow rate
163WElectric power input of the fan drive at maximum flow
rate
47dBSound power level (LWA)
0.077m
3
/sReference flow rate
50PaReference pressure difference
0.242W/m
3
/hSpecific power input (SPI)
Clock control (0.95)Control factor and control typology
Internal: 2.0
External: 1.6
%External leakage rates
See user manual.Information about filter warning
See the "Ventilation connections" section.Information about supply/exhaust grilles in the facade
See the "Recovery" section.
This installer manual can also be accessed at nibe.eu.
Information about pre-/disassembly
318kWh/yearThe annual electricity consumption
Average: 4,383
Cold: 8,770
Warm: 2,027
kWh
prim/year
Annual heating saved, kWh primary energy per year
47Chapter 10 | Technical dataNIBE ERS S10-400