degree minute setting
FXUUHQW YDOXH
VWDUW FRPSUHVVRU
VWDUW GLII DGGLWLRQDO KHDW
GLII EHWZHHQ DGGLWLRQDO VWHSV
'0
'0
'0
'0
GHJUHH PLQXWH VHWWLQJ 
current value
Setting range: -3000 3000
start compressor
Setting range: -1000 -30
Default value: -60
start diff additional heat
Setting range: 100 1000
Default value: 400
diff. between additional steps
Setting range: 0 1000
Default value: 100
Menu
4.9.3
Degree minutes are a measurement of the current heating requirement
in the house and determine when the compressor respectively additional
heat will start/stop.
Caution
Higher value on "start compressor" gives more compressor starts, which
increases wear in the compressor. Too low value can give uneven indoor
temperatures.
factory setting user
'R \RX ZDQW WR UHVHW DOO XVHU VHWWLQJV WR
IDFWRU\ VHWWLQJV"
IDFWRU\ VHWWLQJ XVHU 
\HV
QR
All settings that are available to the
user (including advanced menus) can
be reset to default values here.
Menu
4.9.4
Caution
After factory setting, personal set-
tings such as heating curves must be
reset.