to the climate system. This means that F1255 never calculates a temperature
lower than that set here.
If there is more than one climate system the setting can be made separately for
each system.
TIP
The value can be increased if you have, for example, a cellar that you
always want to heat, even in summer.
You may also need to increase the value in "stop heating" menu 4.9.2
"auto mode setting".
ROOM SENSOR SETTINGS
room sensor settings 1.9.4
heating factor system1
control room sensor syst 2
control room sensor syst 3
cooling factor system 1
control room sensor syst
control room sensor syst 4
factor system
heating
Setting range: 0.0 - 6.0
Factory setting heating: 1.0
cooling (accessory required)
Setting range: 0.0 - 6.0
Factory setting cooling: 1.0
Menu
1.9.4
Room sensors to control the room temperature can be activated here.
Caution
A slow heating system such as underfloor heating may not be suitable
for control using the installation’s room sensors.
Here you can set a factor (a numerical value) that determines how much an over
or sub normal temperature (the difference between the desired and actual room
temperature) in the room is to affect the supply temperature to the climate
system. A higher value gives a greater and faster change of the heating curve's
set offset.
NOTE
Too high a set value for "factor system" can (depending on your climate
system) produce an unstable room temperature.
NIBE F1255Chapter 3 | F1255 at your service36