PLUS FUNCTIONS
plus functions4.1
pool
internet
sms
smart price adaption
Settings for any additional functions in-
stalled in F1255 can be made in the sub
menus.
Menu
4.1
POOL (ACCESSORY IS REQUIRED)
pool4.1.1
activated
start temp
stop temperature
°C
°C
compressor speed
%
start temp
Setting range: 5.0 - 80.0 °C
Default value: 22.0 °C
stop temperature
Setting range: 5.0 - 80.0 °C
Default value: 24.0 °C
compressor speed
Setting range: 1 100 %
Factory setting: 1 %
Menu
4.1.1
Select whether the pool control is to be activated and within what temperatures
(start and stop temperature) pool heating must occur.
Here you can also set at what speed the compressor is to operate during pool
heating. Set value corresponds to part of the available output.
When the pool temperature drops below the set start temperature and there is
no hot water or heating requirement, F1255 starts pool heating.
Untick "activated" to switch off the pool heating.
Caution
The start temperature cannot be set to a value that is higher than the
stop temperature.
INTERNET
Menu
NIBE F1255Chapter 3 | F1255 at your service54

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nibe F1255 Series and is the answer not in the manual?

Nibe F1255 Series Specifications

General IconGeneral
BrandNibe
ModelF1255 Series
CategoryHeat Pump
LanguageEnglish

Related product manuals