Mechanical Connection of F2040
Connect to the unit using the supplied flexible hoses with minimum use of elbows.
The Flexible hose incorporating a Manual air vent must be on the flow pipe (top connection).
Flexis/pipework must be insulated and weatherproofed with a UV stable product.
Exposed pipework must be kept to a minimum.
Pipework routed below ground must be low heat loss and kept to the minimum possible length.
Condensation will be produced by and drip from below the unit. This must be safely routed to a drain/soakaway,
avoiding ingress on walkways.