Type | Air/Water Heat Pump |
---|---|
Operating Temperature Range | -25°C to +45°C |
Refrigerant | R410A |
Max. Flow Temperature | 65°C |
Heating Capacity | 8-20 kW |
Power Supply | 3-phase, 400V |
SCOP | 5.0 (Model dependent, refers to average climate, low temperature application) |
Manual describes installation and service procedures for implementation by specialists.
Explanation of symbols used in the manual for warnings, notes, and tips.
Information on CE mark and IP24 classification for equipment.
Location and importance of the 14-digit serial number for service.
Instructions for proper disposal of packaging and the product.
Details about refrigerant R410A and its Global Warming Potential.
Checklist for mandatory heating installation inspection before commissioning.
Table showing compatibility between F2120 models and various modules.
Guidelines for transporting and storing the F2120 unit vertically.
Instructions for outdoor placement, foundation requirements, and noise considerations.
Information about the compressor heaters and their activation before start-up.
Details on condensation water management, drainage, and heating cable.
Required clearances around the F2120 unit for installation and servicing.
List and images of components supplied with F2120-8, -12 and -16, -20 models.
Illustrations showing how to remove the side cover and top panel for access.
Diagram of the F2120 (1x230V) with labeled internal components.
Diagram of the F2120 (3x400V) with labeled internal components.
General guidelines for pipe installation according to norms and directives.
Information on the charge pump's function, anti-freezing, and periodic operation.
Requirement for available water volume to prevent short operating times and enable defrosting.
Instructions for venting, installing filter, and connecting pipes for the heating medium circuit.
Graph showing pressure drop versus flow for different F2120 models.
Diagram illustrating heat insulation for the pipes connected to the unit.
Diagram showing the connection of flex hoses to the unit.
General requirements for electrical connections, including permissions and qualified electricians.
Illustrations for removing the side cover to access electrical connections.
Instructions for setting communication address and functions using DIP switches.
Details on power connection, including cable routing and tightening torque.
Instructions for connecting external control voltage and wiring for tariff control.
Information on connecting the KVR 10 heating cable for the condensation water pipe.
Recommended routing for electrical and heating cables from the distribution box.
Instructions for communication setup with NIBE indoor/control modules.
Checklist for system preparation, leaks, electrical connections, and compressor heater activation.
Definition of balance temperature and its relation to building output requirement.
Steps for filling and venting the heating medium system using the venting nipple.
Procedure for starting up the unit, including checks, settings, and reporting.
Steps for venting air and stabilizing the system for heating operation.
Recommendations for adjusting charge flow for optimal heat pump function, especially with water heaters.
Overview of the F2120's internal controller and communication with NIBE modules.
Explanation of the six status LEDs on the base board for control and fault tracing.
Description of how control settings are made via the NIBE indoor module/control module.
Details on control conditions, particularly for defrosting modes (active and passive).
Explanation of settings within the HEAT PUMP MENU 5.11.1.1 for silent mode, phase detection, and current limit.
General guide to rectifying comfort disruptions by checking alarms and basic actions.
Steps to troubleshoot communication issues between F2120 and indoor/control module.
Troubleshooting steps for issues related to hot water supply, including consumption and filter checks.
Troubleshooting steps for low room temperature, including thermostat settings and flow issues.
Troubleshooting steps for high room temperature, primarily related to incorrect module settings.
Actions to resolve ice build-up, including activating 'de-icing fan' and checking airflow.
Troubleshooting for water accumulation below the unit, requiring KVR 10 and checking drainage.
Table listing alarms, their text, description, and possible causes for F2120.
List of available accessories for the F2120, including condensation water pipes of different lengths.
Diagrams showing the dimensions of F2120-8 and F2120-12, -16, -20 models.
Table detailing sound power and pressure levels at various distances for F2120 models.
Detailed technical specifications including heating, cooling, electrical, and refrigerant data.
Graphs illustrating the operating ranges (supply vs. outdoor temperature) for heating and cooling.
Graphs showing output and COP at different supply temperatures for F2120-8 and F2120-12.
Graphs showing output at different supply temperatures for cooling capacity.
Information sheet detailing energy efficiency ratings for the F2120 models.
Wiring diagram for F2120 (230V) showing component connections and layout.
Wiring diagram for F2120 (400V) showing component connections and layout.