Page | 8
Electrical Connection of F2040
F2040 Communication board (AA23)
The mains cable is pre-wired in the unit and must be terminated in a local rotary isolator. (not a cooker switch)
The rotary isolator must be supplied by 6 or 10 Square cable back to the Fuse board. (dependent on distance and
sized by the electrician)
The circuit breaker must be 25 Amp “motor” rated.
The communication (comms) cable must be screened cat5 or equivalent. It must also be separated from power supply
runs and the foil screen grounded on one end only.