F-series VVM / SMO
These settings are made on the display on the indoor mod-
ule/control module.
MENU 5.11.1.1 - HEAT PUMP
Here, you make specific settings for the installed heat pump.
Cooling permitted
Setting range: off / on
Silent mode permitted
Setting range: yes / no
Detect compressor phase
Setting range F2050 1 x 230 V: off/on
Current limit
Setting range: 6 32 A
Factory setting: 32 A
blockFreq 1
Setting range: yes / no
blockFreq 2
Setting range: yes / no
Cooling permitted: Here, you can set whether the cooling
function will be activated for the heat pump.
Silent mode permitted: Here, you set whether silent mode
will be activated for the heat pump. Please note that you
now have the option to schedule when silent mode will be
active.
The function should only be used for limited periods, because
F2050 possibly may not reach its dimensioned output.
Detect compressor phase: This shows in which phase the
heat pump detected that you have F2050 230V~50Hz. Phase
detection normally occurs automatically in connection with
start-up of the indoor module/control module. This setting
can be changed manually.
Current limitation: Here, you set whether the current lim-
itation function will be activated for the heat pump, if you
have F2050 230V~50Hz. During active function, you can
limit the value of the maximum current.
BlockFreq 1: Here, you can select a frequency range within
which the heat pump is not permitted to work. This function
can be used if certain compressor speeds cause disturbing
noise in the house.
BlockFreq 2: Here, you can select a frequency range within
which the heat pump is not permitted to work.
NIBE F2050Chapter 7 | Control Heat pump EB10134