OPERATING INSTRUCTIONS
NIBE
TM
F205P
Front panel
The operating instructions describe the most important
functions and the regular maintenance required for F205P
and its ventilation equipment.
For detailed information, see Assembly and Operating
Instructions.
General
Switch
Pressure gauge
Thermometer
Warning lamps
Hot water priority (hidden*)
Circulation pump (hidden*)
A
B
C
D
F
E
Thermometer
The boiler temperature is indicated here. The value
depends on the cut-off temperature of the electric
heater element, the set value for the cut-off tem-
perature of the compressor and the quantity of hot
water drawn off.
A
C
Indicators lamps
Upper lamp
Lit Compressor in operation.
Flashing Alarm for actuated pressure regula-
tors or indication of stand-by operation.
(Compressor blocked).
Unlit Compressor not in operation.
Middle lamp
Lit Defrosting in progress.
Flashing Air filter requires cleaning.
Lower lamp
Lit Electric heater element in operation.
Not lit Electric heater element not in operation.
D
Switch
0 Heat pump switched off completely
1 Fan in operation. The compressor and the circu-
lation pump are started up as required.
2 Fan in operation. The compressor, the electric
heater element and the circulation pump are
started up as required.
3 Stand-by mode. Fan in operation. Compressor
not in operation. The electric heater element
and the circulation pump are started up as re-
quired.
Pressure gauge
The radiator circuit pressure is indicated here. The
gauge is
graduated from 0 – 4 bar. Normal pressure is 0.5 –
1.5 bar.
B
E
Hot water priority
Auto Hot water priority permanently activated
(same function as "1")
1 Hot water priority permanently activated.
0 Hot water priority not activated.
F
Circulation pump
with 2 positions “Auto” - “1”:
Auto The circulation pump is switched on and
off by the control system or the clock ther-
mostat.
1 Circulation pump in continuous operation.
*These functions are accessible after removing the upper front cover.