TIP
Set the stop time earlier than the start time so that the period extends
beyond midnight. Scheduling then stops at the set stop time the day
after.
Scheduling always starts on the date that the start time is set for.
advanced
advanced 2.9
periodic increase
hot water recirc.
Menu advanced has orange text and
is intended for the advanced user. This
menu has several sub-menus.
Menu
2.9
periodic increase
periodic increase 2.9.1
activated
period
start time
Next periodic increase
days
period
Setting range: 1 - 90 days
Default value: 14 days
start time
Setting range: 00:00 - 23:00
Default value: 00:00
Menu
2.9.1
To prevent bacterial growth in the water heater, the compressor and the
immersion heater can increase the hot water temperature for a short time
at regular intervals.
The length of time between increases can be selected here. The time can
be set between 1 and 90 days. Factory setting is 14 days. Tick/untick "ac-
tivated" to start/switch off the function.