In most cases, the main product notes a malfunction (a
malfunction can lead to disturbance in comfort) and indic-
ates this with alarms and shows action instructions in the
display.
Troubleshooting
If the operational interference is not shown in the display
the following tips can be used:
BASIC ACTIONS
Start by checking the following items:
That the heat pump is operating and the supply cable to
SAM S42 is connected.
Group and main fuses of the accommodation.
The property's earth circuit breaker.
LOW HOT WATER TEMPERATURE OR A LACK OF
HOT WATER
The heat pump has temporarily prioritised supply air
ventilation to prevent too low temperatures in the supply
air coil.
LOW ROOM TEMPERATURE
Incorrectly set values for the supply air temperature.
Enter menu 7.2.9 - "Supply air module (SAM)" and adjust
the setting for the supply air temperature.
HIGH ROOM TEMPERATURE
Incorrectly set values for the supply air temperature.
Enter menu 7.2.9 - "Supply air module (SAM)" and adjust
the setting for the supply air temperature.
LOW OR A LACK OF VENTILATION
Supply air filter (HQ11) clogged.
Change the filter.
The ventilation is not adjusted.
Order/implement ventilation adjustment.
Supply air device closed, blocked or throttled down too
much.
Check the supply air inlets.
Fan speed in reduced mode.
Enter menu 1.2.1 - "Fan speed" and select "Normal"
External switch for changing the fan speed activated.
Check any external switches.
Check external frost protection (outdoor air damper).
HIGH OR DISTRACTING VENTILATION
Supply air filter (HQ11) clogged.
Change the filter.
The ventilation is not adjusted.
Order/implement ventilation adjustment.
Supply air device closed, blocked or throttled down too
much.
Check the supply air inlets.
Fan speed in forced mode.
Enter menu 1.2.1 - "Fan speed" and select "Normal"
External switch for changing the fan speed activated.
Check any external switches.
Silencers not correctly installed.
Check the silencers.
LOW SUPPLY AIR TEMPERATURE
Air in the heating system.
Vent SAM S42 using vent valve (QM20.1) and (QM20.2).
Incorrectly set values for the supply air temperature.
Enter menu 7.2.9 (Supply air module (SAM)) and adjust
the setting for the supply air temperature.
HIGH SUPPLY AIR TEMPERATURE
Incorrectly set values for the supply air temperature.
Enter menu 7.2.9 (Supply air module (SAM)) and adjust
the setting for the supply air temperature.
21Chapter 8 | Disturbances in comfortSAM S42
Disturbances in comfort