Service menus
VVM 240
42
Operating settings
Menu 9.3.0 Operating settings
Settings regarding the electric boiler, floor drying and
a return to the factory settings can be made on the
sub-menus in this menu.
Operating settings
9.3.0
Menu 9.3.3 Extra Shunt Present
This menu is used to select On or Off depending on
whether you have shunt group 2 (accessories need-
ed).
Off
Extra Shunt Present
9.3.3
Menu 9.3.4 Room unit
Accessories are needed.
Room unit
9.3.4
Menu 9.3.5.0 Floor drying
Settings for the floor drying program are made in the
sub-menus to this menu.
Floor drying
9.3.5.0
Menu 9.3.2 Electric boiler
Electric boiler mode is actuated when Yes is shown on
the display, otherwise No is displayed. When the elec-
tric boiler mode is activated, the immersion heater
respective circulation pump cannot be blocked with
the operating mode button.
No
Electric boiler
9.3.2
Menu 9.3.1 Max. Boilertemp.
The setting selected on the load monitor card (2) knob
(102) is shown here.
80°C
Max. Boilertemp.
9.3.1
Menu 9.3.5.1 Floor drying
This sub-menu is used to select whether the floor dry-
ing program should be On or Off. After time period 1
switching to time period 2 then return to normal set-
tings.
Off
Floor drying
9.3.5.1
Menu 9.3.5.2 Numb. of days per. 1
Selection of the number of days in period 1.
The value is adjustable between 1 to 5 days.
3 Days
Numb. of days per. 1
9.3.5.2
Menu 9.3.5.3 Temp per. 1
Selection of the flow temperature in period 1.
The value is adjustable between 15 and 50 °C.
25°C
Temp per. 1
9.3.5.3
S
S
S
S
S
S
S
S
S
Menu 9.3.5.4 Numb. of days per. 2
Selection of the number of days in period 2.
The value is adjustable between 1 to 5 days.
1 Day
Numb. of days per. 2
9.3.5.4