Set the speed at which the charge pump is to operate
in the present operating mode. Select "auto" if the speed
of the charge pump is to be regulated automatically
(factory setting) for optimal operation.
If "auto" is activated for heating operation, you can also
make the setting "min. allowed speed" and "max. allowed
speed", which restricts the charge pump and prevents
it from running at a lower or higher speed than the set
value.
For manual operation of the charge pump, deactivate
"auto" for the current operating mode and set the value
to between 1 and 100% (the previously set value for
"max. allowed speed" and "min. allowed speed" no longer
applies).
Speed in wait mode (only used if "auto" has been selec-
ted for "Operating mode") means the charge pump oper-
ates at the set speed during the time when neither
compressor operation nor additional heat are required.
5.12 - COUNTRY
Select here the country in which the product was in-
stalled. This allows access to country-specific settings
in your product.
Language settings can be made regardless of this selec-
tion.
Caution
This option locks after 24 hours, after restarting
the display and during program updating.