TIP
Wait 24 hours before making a new setting, so that the room temperature
has time to stabilise.
If it is cold outdoors and the room temperature is too low, increase the curve
slope in menu 1.9.1 by one increment.
If it is cold outdoors and the room temperature is too high, lower the curve
slope menu 1.9.1 by one increment.
If it is warm outdoors and the room temperature is too low, increase the
value in menu 1.1 by one increment.
If it is warm outdoors and the room temperature is too high, reduce the
value in menu 1.1 by one increment.
scheduling
You can also schedule a longer period during a selected period (vacation) in
menu 4.7.
Menu
1.3
heating
Increases or decreases in the accommodation temperature can be scheduled
here for up to three time periods per day. If a room sensor is installed and
Menu
1.3.1
activated the desired room temperature (°C) is set during the time period.
Without an activated room sensor the desired change is set (of setting in
menu 1.1). A one degree change in room temperature requires one increment
for underfloor heating and approximately two to three increments for the
radiator system.
If two settings conflict with each other a red exclamation mark is displayed
at the end of the line.
NIBE™ VVM 500Chapter 3 | VVM 500 at your service26