TIP
Wait 24 hours before making a new setting, so that the room temperature
has time to stabilise.
If it is cold outdoors and the room temperature is too low, increase the curve
slope by one increment.
If it is cold outdoors and the room temperature is too high, lower the curve
slope by one increment.
If it is warm outdoors and the room temperature is too low, increase the
curve offset by one increment.
If it is warm outdoors and the room temperature is too high, lower the curve
offset by one increment.
exter nal adjustment
H[WHUQDO DGMXVWPHQW 
FOLPDWH V\VWHP
FOLPDWH V\VWHP
FOLPDWH V\VWHP
FOLPDWH V\VWHP
r&
r&
climate system
Setting range: -10 to +10 or desired room temperature if the room sensor
is installed.
Default value: 0
Menu
1.9.2
Connecting an external contact, for example, a room thermostat or a timer
allows you to temporarily or periodically raise or lower the room temperature.
When the contact is on, the heat curve offset is changed by the number of
steps selected in the menu. If a room sensor is installed and activated the
desired room temperature (°C) is set.
NIBE™ VVM 500Chapter 3 | VVM 500 at your service32