If there is more than one climate system the setting can be made separately
for each system.
min. flow line temp.
climate system
Setting range: 5-70 °C
Default value: 20 °C
Menu
1.9.3
Set the minimum temperature on the supply temperature to the climate sys-
tem. This means that VVM 500 never calculates a temperature lower than
that set here.
If there is more than one climate system the setting can be made separately
for each system.
TIP
The value can be increased if you have, for example, a cellar that you always
want to heat, even in summer.
You may also need to increase the value in "stop heating" menu 4.9.2 "auto
mode setting".
33NIBE™ VVM 500Chapter 3 | VVM 500 at your service