room sensor settings
URRP VHQVRU VHWWLQJV 
IDFWRU V\VWHP
FRQWURO URRP VHQVRU V\VW
FRQWURO URRP VHQVRU V\VW
IDFWRU V\VWHP
FRQWURO URRP VHQVRU V\VWHP
FRQWURO URRP VHQVRU V\VW
factor system
Setting range: 0.0 - 6.0
Default value: 2.0
Menu
1.9.4
Room sensors to control the room temperature can be activated here.
Here you can set a factor that determines how much the supply temperature
is to be affected by the difference between the desired room temperature
and the actual room temperature. A higher value gives a greater change of
the heating curve's set offset.
If several climate systems are installed the above settings can be made for
the relevant systems.
NIBE™ VVM 500Chapter 3 | VVM 500 at your service34