EasyManuals Logo

Nibe VVM S320 Installer Manual

Nibe VVM S320
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #41 background imageLoading...
Page #41 background image
Own curve, cooling
Supply temp
Setting range: -5 40 °C
Caution
Curve 0 must be selected for own curve to apply.
You can create your own cooling curve here, if there are
special requirements, by setting the desired supply temper-
atures for different outdoor temperatures.
MENU 1.30.8 - POINT OFFSET
outdoor temp. point
Setting range: -40 30 °C
change in curve
Setting range: -10 10 °C
Select a change in the heating curve at a certain outdoor
temperature here. One step is usually enough to change the
room temperature by one degree, but in some cases several
steps may be required.
The heating curve is affected at ± 5°C from set outdoor
temp. point.
It is important that the correct heating curve is selected so
that the room temperature is experienced as even.
TIP
If it feels cold in the house at e.g. -2°C, "outdoor
temp. point" is set to "-2" and "change in curve" is
increased until the desired room temperature is
maintained.
Caution
Wait 24 hours before making a new setting, so that
the room temperature has time to stabilise.
41Chapter 9 | Control MenusNIBE VVM S320