This is a “hardware” type of disabling function, very simple to do but, consequently, very easy
to undo by an intruder.
There is also another type of disabling function, a “software” type, more difficult to manage but
extremely secure in that only a previously authorised remote control can be used to restore it (see
activating/deactivating the 2
nd
disabling function).
Still on the subject of safety, there is another even more secure type of disabling function, which is
controlled by a “PASSWORD”. Only a portable accessory BUPC manages this function.
ADJUSTMENTS AND SETTINGS
Selection of the relays on the channels
Each receiver can recognise all 4 transmitter channels, also simultaneously.
Association of the channel to the relay is fixed and depends on the relay’s position. Different types of
relay modules can be plugged into the connectors which differ in the kind of function they perform.
In the normal functioning mode the relay in output is a temporary type, that is, it is energised a few
seconds after the transmitter key has been pressed (delay due to code recognition time) and it de-
energises 300mS after the key has been released.
- 37 -