EasyManuals Logo

Nice LP21 User Manual

Nice LP21
37 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #22 background imageLoading...
Page #22 background image
LP21/LP22
Pag. 22 a 37
LP21/LP22 Installation instructions en Sensors
The following parameters can be adjusted with the DIP switch:
DIP switch
Position
Value
Sense 1a / 2a
ON
0.01% (high)
Sense 1b / 2b
ON
Sense 1a / 2a
OFF
0,04%
Sense 1b / 2b
ON
Sense 1a / 2a
ON
0,16%
Sense 1b / 2b
OFF
Sense 1a / 2a
OFF
0.64% (low)
Sense 1b / 2b
OFF
Frequency
OFF
low
ON
high
Hold time
OFF
5 minutes
ON
Infinite
Output 2
OFF
Continuous signal
ON
Pulse signal
Edge 2
OFF
on entering
ON
on leaving
Inv. Out 1
OFF
Output inverted
ON
Output not inverted
Inv. Out 2
OFF
Output not inverted
ON
Output inverted
Dir. Mode
OFF
Presence
ON
Direction
Dir. Logic
OFF
Continuous signal 2
ON
Wrong-way driver 1
Tab.12: Settings via DIP switch (LP22)

Other manuals for Nice LP21

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nice LP21 and is the answer not in the manual?

Nice LP21 Specifications

General IconGeneral
BrandNice
ModelLP21
CategorySecurity Sensors
LanguageEnglish

Related product manuals