LP21/LP22
Pag. 22 a 37
LP21/LP22 Installation instructions en Sensors
The following parameters can be adjusted with the DIP switch:
DIP switch
Position
Value
Sense 1a / 2a
ON
0.01% (high)
Sense 1b / 2b
ON
Sense 1a / 2a
OFF
0,04%
Sense 1b / 2b
ON
Sense 1a / 2a
ON
0,16%
Sense 1b / 2b
OFF
Sense 1a / 2a
OFF
0.64% (low)
Sense 1b / 2b
OFF
Frequency
OFF
low
ON
high
Hold time
OFF
5 minutes
ON
Infinite
Output 2
OFF
Continuous signal
ON
Pulse signal
Edge 2
OFF
on entering
ON
on leaving
Inv. Out 1
OFF
Output inverted
ON
Output not inverted
Inv. Out 2
OFF
Output not inverted
ON
Output inverted
Dir. Mode
OFF
Presence
ON
Direction
Dir. Logic
OFF
Continuous signal 2
ON
Wrong-way driver 1
Tab.12: Settings via DIP switch (LP22)