LP21/LP22 Installation instructions en Sensors
8.2.2 DIP switch assignment of the LP22 variants
The 2 channel versions have an 8-pole and 4-pole DIP switch for configuring the detector.
DIP1
Label
Function
1
Sense 1a
Loop 1 sensitivity
2
Sense 1b
Loop 1 sensitivity
3
Sense 2a
Loop 2 sensitivity
4
Sense 2b
Loop 2 sensitivity
5
Frequency
Frequency level
6
Hold time
Hold time until readjustment
7
Output 2
Output signal 2 mode
8
Edge 2
Time output signal 2
Tab.10: DIP switch 1 occupancy (standard)
DIP2
Label
Function
1
Dir. Mode
Direction detection
2
Dir. Logic
Direction logic
3
Inv. Out 1
Output signal 1 inversion
4
Inv. Out 2
Output signal 2 inversion
Tab.11: DIP switch 2 occupancy (standard)