EasyManuals Logo

Nice MBar User Manual

Nice MBar
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #9 background imageLoading...
Page #9 background image
COMMAND CONFIGURATION
This item covers the command categories associable with inputs 1 - 2 - 3 (refer to the section “input conguration - Table 1” to check the commands avail-
able). Each command category features various operating modes as described in a table (1-A, 1-B, etc.):
Step-by-step
In this command category the user can select one of the operating modes specied in Table 1-A.
TABLE 1-A: COMMAND CONFIGURATION
MODE DESCRIPTION
Industrial mode
This runs the sequence “open in semiautomatic- close in hold-to-run”.
Open - stop - close - stop
This executes the above sequence.
Open - Stop - Close - Open
Operating mode set in factory (Input 1 - “step-by-step” command). This executes the above sequence.
Open - Close - Open - Close
This executes the above sequence.
Apartment block 1 step-by-step
Runs the sequence “close - stop - open - open”, until it reaches the fully open position. Note – If another command
is sent after this one, the application executes the Closing manoeuvre with the same sequence.
Apartment block 2 step-by-step
Runs the sequence “close - stop - open - open” until the fully open position is reached. Note – If another command
is sent after this one, the application executes the Closing manoeuvre with the same sequence. Important – When
sending a command, if the transmitter key is held down for more than 2 seconds, the control unit activates a Stop.
Step-by-step 2
This executes the sequence “open - stop - close - open”. Important – When sending a command, if the transmitter
key is held down for more than 2 seconds, the control unit activates a “partial open 1” command (input congura-
tion > Table 1).
Hold-to-run
The Opening or Closing manoeuvre is executed exclusively if the transmitter key is held down (hold-to-run).
partial open
In this command category the user can select one of the operating modes specied in Table 1-B.
TABLE 1-B: COMMAND CONFIGURATION
MODE DESCRIPTION
Open - stop - close - stop Operating mode set in factory. This executes the above sequence.
Open - Stop - Close - Open This executes the above sequence.
Open - Close - Open - Close This executes the above sequence.
Apartment block 1 step-by-step This executes the sequence “close - stop - partial open 1- partial open 1” until the position is reached as pro-
grammed in the function “Partial Open 1”. Note – If another command is sent after this one, the application executes
the Closing manoeuvre with the same sequence.
Apartment block 2 step-by-step This executes the sequence “close - stop - partial open 1 - partial open 1” until the position is reached as pro-
grammed in the function “Partial Open 1”. Note – If another command is sent after this one, the application executes
the Closing manoeuvre with the same sequence. Important When sending a command, if the transmitter key is
held down for more than 2 seconds, the control unit activates a Stop.
Hold-to-run The Partial open 1 or Closing manoeuvre is executed exclusively if the transmitter key is held down (hold-to-run).
Industrial mode This runs the sequence “open in semiautomatic- close in hold-to-run”.
Open
In this command category the user can select one of the operating modes specied in Table 1-C.
TABLE 1-C: COMMAND CONFIGURATION
MODE DESCRIPTION
Open - Stop - Open Operating mode set in factory (Input 2 - “open” command). This executes the above sequence.
Apartment block 1 An Opening manoeuvre is executed.
Apartment block 2 This executes the sequence “open - open”. Important When sending a command, if the transmitter key is held
down for more than 2 seconds, the control unit activates a Stop.
Open 2 Important – When sending a command, if the transmitter key is held down for more than 2 seconds, the control unit
activates a “partial open 1” command (input conguration > Table 1).
Hold-to-run Open The Opening manoeuvre is executed exclusively if the transmitter key is held down (hold-to-run).
Close
In this command category the user can select one of the operating modes specied in Table 1-D.
TABLE 1-D: COMMAND CONFIGURATION
MODE DESCRIPTION
Close - stop - close Operating mode set in factory (Input 3 - “close” command). This executes the sequence as described.
Apartment block 1 close This executes the sequence “close - close”.
Apartment block 2 close This executes the sequence “close - close”. Important When sending a command, if the transmitter key is held
down for more than 2 seconds, the control unit activates a Stop.
Hold-to-run close The Closing manoeuvre is executed exclusively if the hold-to-run command is used.
Stop
In this category, you can choose one of the operating modes listed in table 1-E.
TABLE 1-E: COMMAND CONFIGURATION
MODE DESCRIPTION
Stop Operating mode set in factory. When the control unit receives the command, it stops the manoeuvre in progress
gradually and in a short time (not instantly).