Signals emitted by LED B of the receiver
Longashes>GREEN
On start-up:
1 Z =
Current encoding system: “Flo”
2 Z =
Current encoding system: “O-Code” / “O-Code/A” / “FloR” / “FloR/A”
3 Z =
Current encoding system: “Smilo”
5 Z =
No remote control memorised
During operation:
1 Z =
Indicates that the code received is not stored in the memory
3 Z =
Saving code in memory
5 Z =
Memory deleted
6 Z =
During programming, indicates that the code is not authorised for memorisation
8Z =
During programming, indicates that the memory is full
Shortashes>GREEN
1 Z =
“Certicate”notvalidformemorisation
2 Z =
During programming, indicates that the code cannot be memorised because it transmits the “cer-
ticate”
4 Z =
Output in “Mode 2” not managed on control unit