13
Electrical and electronic installaon and setup.
As a motorised operator vibrates when in use, it is strongly recommended that only mulple strand exible cables be used.
Before closing the unit, always remember to double check that all connecons are securely made, that there are no stray strands aring out that can
short circuit against other adjacent connecons or bared wires and that no cables will be pulled loose when the cover is replaced on the unit.
Double check the baery connecons as loose connecons can cause arcing and corrosion of the baery terminals.
Terminang the AC voltage:
The ACDC power supply requires 220Vac at the operator. This 220Vac must be circuited through a weatherproof all pole isolator switch. This isolator
switch must be installed within 1,5m of the unit, must not be installed within the workings of the system and must be posioned so that it cannot
be tampered with for the outside of the property. This circuit must be cered by way of a C.O.C. (cercate of compliance) issued by a registered
electrician.
The following shows the wiring of the 220Vac and how to access the 2A fast blow 20mm x 5mm fuse located within the power supply module.
Connecng the 220Vac supply:
O On O On
Ensure the 220Vac has been isolated. Terminate the 220Vac and earth as shown here. Switch the 220Vac back on.
220Vac live.
Earth.
220Vac neutral.