5. It is highly recommended that a set of safety infra-red beams be used in conjuncon with this product. The safety beams must be
installed in such a way that the product is prevented from running when anything is in the path of the door or barrier.
6. Over and above the recommendaon to use safety infra-red beams with this product it is mandatory to install and use a safety
beam set when using the automac closing feature. It is recommended that a warning light be ed to any automaon system.
7. The barrier or door warning labels must be installed in a prominent place and/or adjacent to any xed controls that trigger the
system. These must be in clear line of sight of the barrier or door opening.
8. The emergency manual release instrucon label must be installed on or adjacent to the emergency manual release mechanism.
Aer installaon - It is the responsibility of the installer to ensure the users:
1. Is procient in the use of the manual emergency release mechanism.
2. Is issued with the documentaon accompanying this product.
3. Understands that the barrier or door may not be operated out of clear sight.
4. Ensures that children are kept clear of the barrier or door area at all mes, and that children do not play with the remote
transmiers or any xed trigger switches linked to the system.
5. Is instructed not to aempt to repair or adjust the automaon system and to be aware of the danger of connuing to use the
automaon system in an unsafe condion before a service provider aends to it.
6. Is procient in tesng the unit’s safety obstrucon sensing system.
7. Is aware of what to check for with regards to wear and tear that may need to be aended to from me to me by the service
provider.
8. Is aware that a fagued baery may not be disposed of in the general refuse and must be handed in at a baery merchant for safe
disposal. Before removing the baery from the system the household mains must be disconnected. In the case of the motor unit
being removed and scrapped, the baery must be removed rst.
TECHNICAL SPECIFICATIONS
Technical Data WIDE M and WIDE L
Primary power supply. 220 – 240Vac @ 50Hz – 60Hz.
Peak power consumpon. 240W
Electrical class. Class 1.
Motor voltage. 24Vdc.
Motor current. Current limited to 10A.
Built in baery charger. Mulple stage auto-calibrang (Peak - 500mA)
Number of operaons, within 24hrs of power
failure, on baery reserve.
(Baery health and charge level at me of
power failure dependent)
650 Using 1 x 24V 5Ah baery. (Standard in kit)
950 Using 2 x 24V 3.5Ah baeries.
1300 Using 2 x 24V 5Ah baeries.
Maximum operaons per day. 3000
Duty cycle with mains present.
Boom pole open/close speed selecon depen-
dent.
98%
Operang speed.
Wide M = 90°/3,5s.
Wide L = 90°/5s.
Torque.
Wide M = 140Nm.
Wide L = 200Nm.
Operang temperature range. -10 to 50° C (14F to 122F)
An-crushing safety sensing. Yes – Electronic load proling.
Auxiliary supply output. 12Vdc @ 400mA.
Receiver format. ET BLU MIX © backward compable with ET BLUE. (Rolling code)
Receiver frequency. 433.92MHz.
Receiver channels. 4CH (BT, Open only, Aux relay, Holiday lock-out)
Receiver memory capacity. 1023 users.
All users can be allowed control of all channels. Yes.
Ingress protecon. IP44
Physical dimensions. See next page.
Technical specicaons.