After any programming phase, you must run an inspection of the entire
wireless connection system to check operation of the devices present.
Since certain phases of the inspection require checks to be run with the gate
wing moving, during inspection the automation system may not be adequately
safe. Therefore it is recommended to pay maximum attention when running the
checks.
Repeat the entire inspection sequence for each single device present in the wire-
less connection network.
For precautionary reasons, release the motor using the appropriate key, by con-
sulting the respective instruction manual.
01.
Activating the system’s “operation check” procedure:
a) - after creating the system, press and release the WM100 button (fig. 3): this
operation enables the system’s “operation check”; in this phase a manoeuvre
is simulated without actually activating the mechanical components;
b) - move the gate leaf to various points along its travel and check the quality
of the radio communication on each device
The FLW200 flashing light indicates the
radio communication status using the
B leds (fig. 4)
m = led on; l = led off)
m m m = excellent radio
reception
m m l = good radio
reception
m l l = sufficient radio
reception
l l l = insufficient radio
reception
The signals from PHW200 photocells regarding radio quality, the status of
optics and batteries are described in the relevant instruction manual.