C.2 Lighting Procedures (Continued.)
MANUAL IGNITION
Nieco Corporation - Model MPB94
1. Allow the broiler
to run free of
any product for
10 minutes.
This will burn
the chain clean.
2. Turn off the
Main Power
Switch.
3. Wait for 30
minutes
for the
broiler to
cool.
C.3 Shutdown Procedures
PLANNED SHUTDOWN
2. Close the
MAIN GAS
VALVE
Valve is closed when
it is perpendicular to
pipe.
EMERGENCY SHUTDOWN
1. Turn off the
MAIN POWER
SWITCH.
Your Nieco Automatic Broiler is designed to automatically stop gas flow to the broiler in the event of
power failure, gas pressure loss or any other related incident. No attempt to operate this appliance
should be made in the event of a power failure.
CAUTION
In a prominent location, post
instructions to be followed in the
event the user smells gas. This
information shall be obtained by
consulting your local gas supplier.
CAUTION
FOR YOUR SAFETY: Do not store
or use gasoline or other flammable
vapors or liquids in the vicinity of
this or any other appliance.
CAUTION
FOR YOUR SAFETY: In the event of
a prolonged power failure, no
attempt should be made to operate
this appliance.
1. Remove the discharge awning. Turn the MAIN POWER
SWITCH on. For broilers equipped with the EMS controls,
turn the main power switch to position two (2). Hold a
lighter/match to the first upper burner on the discharge
end until the burner lights. Once the first burner is lit, veri-
fy that all burners have ignited.
2. Check GAS PRESSURE GAUGE reading. Gauge
should read 4.5ā*. If the gauge is not easy to see look to
make sure that all burners - upper and lower - have lit.
*For Natural Gas only. For LP broilers gas pressure should be 11ā.
EMS SWITCH
STANDARD SWITCH
EMS SWITCH
STANDARD SWITCH