C.4 Control Operation
IMPORTANT: THIS BROILER IS SHIPPED WITH FACTORY PRESETS THAT MUST BE CHANGED.
If this is the initial start-up for your broiler, ALL control settings must be made according to BURGER KING® specifications. Follow the
s
teps outlined for calibration, changing preset times and setting the flex chamber element heat settings to properly set up this broiler.
Nieco Corporation - Model MPB94
MAIN SIDE CONTROLS
-+

1. SETTING BELT SPEEDS
Lift cover, press and turn the belt speed
control knob to the desired speed setting.
2. LOAD SENSING CONTROL
How it works:
The load sensing control will display
“Rdy” (ready) when the broiler is ready to
cook on.
3. AUTOMATIC CALIBRATION
A. Before turning the broiler on, press
and hold the load sensing control knob
in.
B. Turn the main power switch on and
continue to hold the load sensing control
knob in for 5 seconds.
C. After 5 seconds, release the knob. The
control will display a countdown of 60
minutes. After the countdown, the control
will display “Rdy” (ready), and the broiler
will be calibrated.
IMPORTANT: DO NOT COOK DURING
THE 60 MINUTE COUNTDOWN!
Press and hold for
5 seconds
Automatic
calibration
-+
A
-+
-+


B
C
Display will show
60 minute
countdown