INSTRUCTIONS FOR USE ENGLISH
107412885 - SC100 7
04/2015
RECOVERY TANK CLEANING
(Figure 8)
1. Remove the tank assembly from the machine body by using handle (9).
2. Separate the solution tank (10) from the recovery tank (13).
3. Open the recovery tank by prying on the hooks (A) and (B).
4. Clean with water and detergent the lower (C) and upper (D) compartments of the tank, then rinse carefully.
5. Reassemble the components.
6. If necessary wash the solution tank (10) with clean water.
SOLUTION FILTER CLEANING
(Figure 9)
1. Remove the tank assembly from the machine body.
2. Remove the two rubber gasket (A and B), then remove the lter strainer (C).
3. Clean and install them on the support (D).
AIR FILTER CLEANING
(Figure 10)
1. Remove the cover (A), then remove the air lter (B).
2. Clean the lter.
3. Install the lter in the housing (C) and close with the cover (A).
TROUBLESHOOTING
Trouble Possible Cause Remedy
The machine does not work. The power supply cable or plug is broken. Replace the cable.
The main switch is broken. Replace the main switch. (*)
The push button panel is broken. Replace the push button panel. (*)
The recovery water vacuuming is
insufcient.
The recovery tank is full. Empty the tank.
The squeegee bars are dirty or the blades are worn
or damaged.
Clean and check the squeegee bars.
The inspection compartment is dirty. Clean the compartment.
The recovery vacuum hose is disconnected or dirty. Connect or clean the hose.
The air lter is dirty. Clean the lter.
The solution ow to the brush is
insufcient.
The solution lter is dirty. Clean the lter.
The solution dispensers are clogged. Clean the solution dispensers.
The squeegees leave marks on the
oor.
There is debris under the squeegee blades. Remove the debris.
The squeegee blades are worn, chipped or torn. Replace the blades.
(*) This maintenance procedure must be performed by an authorised Nilsk Service Center.
For further information refer to the Service Manual, available at any Nilsk Service Center.
DISPOSAL
Have the machine scrapped by a qualied scrapper.
Before disposal the machine, remove and separate the following materials, which must be disposed of properly according to the
Law in force:
Brush
Plastic hoses and components
Electrical and electronic components (*)
(*) Refer to the nearest Nilsk Center especially when disposal electrical and electronic components.
107412885(1)04-2015 A.indb 7 16/09/2015 16:54:38

Other manuals for Nilfisk-Advance SC100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nilfisk-Advance SC100 and is the answer not in the manual?

Nilfisk-Advance SC100 Specifications

General IconGeneral
BrandNilfisk-Advance
ModelSC100
CategoryVacuum Cleaner
LanguageEnglish

Related product manuals