EasyManuals Logo

Nilfisk-Advance SPECTRUM 12D User Manual

Nilfisk-Advance SPECTRUM 12D
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background imageLoading...
Page #12 background image
12
1
2
3
4
2
3
4
6
7
1. Disconnect the power cord from the electrical outlet.
Push the Filter Cover Latch (19) downwards so that the
cover (18) is released. Remove the lter cover from cleaner.
2. Grasp at the lter frame and remove the used and dirty
HEPA- lter
3. Grasp at the lter frame and then insert the new HEPA lter
to the cleaner by pushing it in place. (Never touch the lter
media of a HEPA- lter! Doing so may cause a loss of
performance of the HEPA- lter).
4. Snap the Filter Cover back in place at the cleaner.
IMPORTANT!
Never operate the cleaner without the HEPA-Filter in place in the
machine. Note! These machines are not designed for picking up
hazardous - i.e. poisonous dust!
FILTERS - type of lter may vary from different models
On these machines there are two different lters; one pre- lter before the vacuum motor and one exhaust lter.
There are two different types of exhaust lters available to these machines, HEPA- lter and a standard exhaust lter. The HEPA- lter
(High Ef ciency Particulate Air lter) offers better ltration capacity then the standard exhaust lter. The exhaust lters catches any
dirt that may escape from the dust bag, or motor pre lter. Replace the lter every fourth time that the dust bag is changed (more
often in very dusty applications). The exhaust lters are located at the front side of the machine just above the brush base.
The HEPA lter can not be cleaned or washed clean. When the HEPA- lter is clogged it must be replaced.
1.
Unplug the power cord from the electrical outlet.
2.
Release the brush roller by unlocking the bearing
block. Push the button backwards left towards the
unlocking symbol at the brush housing.
3.
Grasp at the bearing block and pull it out from the
brush housing.
4.
Remove the used brush.
5.
Replace the used brush roller with a new one, or
clean and remove all debris from the present brush.
6.
Slide back the brush into the the xed bearing block
in the brush house.
7.
Push the bearing block in its position. Lock it by
turning clockwise.
CHANGING THE HEPA-FILTER
CHANGING OR CLEANING OF THE BRUSH
Always disconnect the power cord before
performing any machine maintenance.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nilfisk-Advance SPECTRUM 12D and is the answer not in the manual?

Nilfisk-Advance SPECTRUM 12D Specifications

General IconGeneral
BrandNilfisk-Advance
ModelSPECTRUM 12D
CategoryVacuum Cleaner
LanguageEnglish

Related product manuals